Supervisor of receiver's signal and
voltage
Voltcheck X is an on board type (installed in your
model) monitoring device for receiver¡¯s servo
signal and voltage level. It can be used to prevent an uncontrollable
situation due to low voltage
or receiver¡¯s faulty servo signal.
Features
Simple installation
Other Voltcheck series provide accurate
voltage information but it is also true that many modelers hesitate make
large squire hole on their beautiful ships. The LED unit is simply installed
on round hole.
On board type
Voltcheck X can be installed on your model and when receiver¡¯s power is
turned on the battery voltage level and the servo signal status are displayed
on the LED indicator.
Monitors receiver¡¯s voltage
Voltcheck X monitors the receiver¡¯s voltage
level at all times so that you can prevent an uncontrollable situation
due to a low voltage level.
|
blue |
green |
red |
4.8 V (4 cells) |
over 5.3 V |
5.1 ~ 4.5
V |
below 4.4
V |
6.0 V (5 cells) |
over 6.7 V |
6.4 ~ 5.5
V |
below 5.4
V |
Receiver's signal to servo supervision
Voltcheck X monitors the receiver
signal by comparing the standard signal kept in the memory against the
current servo signal so that you can prevent an uncontrollable situation
due to malfunction of receiver caused by damaged parts or connection problem
with a crystal.
Caution : Receiver's signal to
servo supervision is for the signal between receiver and servo. It does
not monitor or supervise the signal between receiver and transmitter.
Therefore, when Fail Safe function is activated due to a malfunction of
transmitter or an interference, receiver locks the servo based on the
fail safe data stored within the receiver. In this case, even though the
transmitter will not be able to control, the signal between the receiver
and the servo is still being sensed normally.
Specification |
|
Voltage range |
4.8 V (4 cells), 6.0 V (5 cells) |
Current drain |
55 mA |
Size |
46 X 25 X 11.8 mm (1.17"
X 0.98" X 0.46") |
Weight |
19.2 g (0.68 oz) |
|